① 99.9% 실재고 관리매일 밤 자동 갱신, 유령 재고 NO! 보이는 수량이 진짜입니다.
② 22년 전문가 직답국내 최고 전문가가 막힘없이 즉시 해결해 드립니다.
③ 확실한 기술 지원국내 최고 수준의 노하우로 막힘없는 솔루션을 제공합니다.
④ 출고 전 전수 촬영출고 전 제품 사진 기록으로 오배송 및 누락을 원천 차단합니다.
⑤ 실시간 배송 일정주문 확인 즉시 발송 예정일을 카톡으로 먼저 알려드립니다.
⑥ Since 2004 신뢰22년을 한결같이 지켜온 믿음. 걱정 없이 이용하세요.
TAROT Retractable Landing Gear Controller - High Power
Tarot사의 대형 Retract Landing Gear(75/90도)용 리트렉터 컨트롤러 세트.
High Power 사양으로서 부하가 많이 걸리는 대형 리트렉터에 적합한 컨트롤러 입니다.(TL4N003/TL4N004 용)
Tarot High Torque perfermance of New Developing Electric Retractable landing gear control system , related items as follow : Electric landing gear controller TL8X002-02 New electric landing gear TL65S01 Small electric landing gear TL65B43 Small electric landing gear group TL65B44 Medium electric landing gear TL8X003 X-series electric landing gear TL96030 Large electric landing gear TL4N001 Large elecric landing gear group TL4N002
1. reverse power protection: The power of positive and negative polarity will not damage the landing gear control panel.
2. the receiver is connected Description: Enter a channel through 3P line even ordinary receiver, the signal for the PWM, pulse width of zero value 1520us, the pulse width is greater than 1520us for landing gear, the pulse width is less than 1520us is closed landing gear.
3. the receiver connection instructions: initial power-up if there is no receiver signal, the indicator flashes rapidly until the receiver detects the signal.
4. Power Protection: After initial power-up if the receiver is close to the landing gear of the action, landing gear does not respond, and the indicator light flashes slowly, until the receiver instruction becomes the landing gear, the light goes out.
5. work instructions: When the retractable landing gear operation is being performed, the indicator lit until the landing gear completely stopped, the light goes out.
6. runaway protection: When the work process, after the loss of receiver signal, the landing gear will automatically put down. How to check whether the motor positive and negative reversed: When the landing gear to work properly, remove the receiver signals to the control panel to enter the failsafe state, if the state is to put the landing gear then the positive and negative electrical wiring is correct, otherwise described motor positive and negative reversed.
Fault diagnosis: 1. the power did not respond: Please check the power of positive and negative connections are correct. 2. the landing gear during the operation to stop in the middle: Please check for foreign objects blocking retractable landing gear. 3. retractable landing gear to perform the action does not respond: Check if foreign objects blocking retractable landing gear. 4. after the landing gear completely stopped, the light does not go out: Check whether the supply voltage to meet the requirements. 5. after power has been rapidly flashing lights: Check the receiver is connected correctly.
Electric retractable tripod control × 1 (47 × 32 × 9.5MM) 13G